Installing ABBYY FlexiCapture components in silent mode

If the silent installation mode is used, no dialog boxes of the Setup Wizard are displayed. To launch this installation mode, run the Setup.exe /qn command.

Note: Change /qn to /qb if you want an installation progress bar to be displayed. No other dialog boxes will be displayed.

Additional command line options

/L<language code> disables the automatic selection of the ABBYY FlexiCapture GUI language and installs the program with the interface language of your choice.

The following language code values can be specified:

  • 1033 English
  • 1049 Russian

/V<command line> passes the command line directly to msiexec.exe. The <command line> string should be replaced with any or a combination of the following commands:

  • INSTALLDIR="<installation directory>"

    The path to the folder where ABBYY FlexiCapture stations should be installed.

  • SETUPTYPE_CMD="<install mode>"

    The installation mode to be used. Available installation modes for ABBYY FlexiCapture Standalone:

    • Full (Administrator Station and Operator Station)
    • Admin (Administrator Station)
    • Operator (Operator Station)
  • ADDLOCAL=ApplicationServer,WebStations,ProcessingServer,ProtectionServer

    The server components of ABBYY FlexiCapture Distributed to install. In this command:

    • ApplicationServer stands for the Application Server
    • WebStations stands for web stations
    • ProcessingServer stands for the Processing Server
    • ProtectionServer stands for the Licensing Server
  • STATIONS=0,1,2,3,4,5,6

    The client components of ABBYY FlexiCapture Distributed to install. The numbers 0 to 6 correspond to the following components:

    • 0 – Scanning Station
    • 1 – Processing Station
    • 2 – Verification Station
    • 3 – Data Verification Station
    • 4 – Project Setup Station
    • 5 – FlexiLayout Studio
    • 6 – FormDesigner
  • ACCOUNTTYPE=Custom, LOGIN=user name, PASSWORD=password

    The account under which to run the Processing Station service.

  • PROTECTIONSERVER=ServerName

    The name of the Licensing Server.

A sample command for installing ABBYY FlexiCapture Standalone:

Setup.exe /qn /L1049 /v INSTALLDIR="D:\FC12" SETUPTYPE_CMD=Full
The program will be fully installed into the D:\FC12 folder and Russian will be selected as the GUI language.

A sample command for installing ABBYY FlexiCapture Distributed server components:

Setup.exe /qn /L1049 /vADDLOCAL=ApplicationServer,WebStations
The Application Server and web stations will be installed and Russian will be selected as the GUI language.

A sample command for installing ABBYY FlexiCapture Distributed client components:

ABBYY FlexiCapture Distributed Setup.exe /qn /L1049 /v INSTALLDIR="D:\FC12" STATIONS=1,4 ACCOUNTTYPE=Custom LOGIN=Domain\UserLogin PASSWORD=PSWD
The Processing Station and the Project Setup Station will be installed into the D:\FC12 folder and Russian will be selected as the GUI language. The Processing Station service will be run under Domain\UserLogin and PSWD will be specified as the password for that account.

Removing ABBYY FlexiCapture components in silent mode

To remove ABBYY FlexiCapture in silent mode, run Msiexec /x {product ID}.

You can find your product ID:

  • In the registry key (the product ID can be found in the key that corresponds to the name of the product):
    • For a 32-bit system
      HKEY_LOCAL_MACHINE\Software\Microsoft\Windows\CurrentVersion\Uninstall
    • For a 64-bit system
      HKEY_LOCAL_MACHINE\Software\Wow6432Node\Microsoft\Windows\CurrentVersion\Uninstall
  • By running the following command: 
    wmic product where "Name like '%FlexiCapture%'" get Name, Version, IdentifyingNumber