Question
How to set up a delay before fetching files via Hot Folder in FineReader Server 14.
Answer
It is possible to set a delay using the Document Library type of workflow. In the Input tab, select the option Crawl the library for new files every N units of time.
This option periodically checks the library for new files. To specify the amount of time between checks, select one of the items from the drop-down list or type the time as "N units of time" (examples: "10 minutes," "6 hours," "3 days").
Please note, that in such a case the minimal delay will be 10 minutes.
More info: Dialog Box: Workflow Properties, Tab: Input (abbyy.com)
Comments
0 comments
Please sign in to leave a comment.