Symptoms
Adding a Processing Station to the Processing Server, the error message is shown:
Error connecting to the station fc-app-server-name.domainname.local: Could not connect to the station fc-app-server-name.domainname.local. Error: Cannot connect to the Application Server. Error: Cannot connect to 'http://fc-app-server-name' (error code: 12007). (15) Unknown error. Error code: 0x2ee7
Cause
The name of the Application Server can't be resolved without the domain name.
Resolution
Use the FQDN of the Application Server in the Processing Server properties. Example:
http://fc-app-server-name.domainname.local
instead of
http://fc-app-server-name